Technical Device Data General Data: Brand, Model: MIMARI MAGNIFICO II PREMIUM (V-SHAPE V8C2) Technical Device Type: Laser Device Serial Number: T16012 Year of Manufacture: 2020 Mileage: Unknown Manufacturer: Beijing Anchorfree Technology CO., Ltd China
Technical data of the item Item Value Model V8C2 Safety class I Class B Type (protection class I; type B according to IEC 60601) Dimensions 620 mm × 520 mm × 1600 mm Net weight 55 kg Input power 850 VA (apparent power) Power supply (Input rating) AC 230 V ± 10% ; 50Hz ± 1Hz Q.C. 01
Functional parameters (according to manufacturer/distributor materials) Area Specification Technologies used Negative pressure (continuous/pulsated) + mechanical rollers + RF (multi-frequency) + IR + 60 kHz cavitation module (integrated with RF in one of the heads). Heads/Applicators Set of 4: large for the body (vacuum + rollers + RF + IR), medium for the limbs, smaller for the face/neck (vacuum + RF + IR) and a 60 kHz cavitation head + RF for the body. Radio waves (RF) Typical frequencies: 0.5 / 0.75 / 1.0 MHz (operating at various depths); total power up to approximately 150 W (depending on the head). 60 kHz cavitation, power up to approximately 60 W (in the head integrated with RF). Infrared (IR) Wavelength: approximately 850 nm; head power typically 16 W (lower) and 40 W (higher), with focusing lenses. Vacuum: Operating range typically up to -75 kPa (continuous or pulsed 1–8 s); high-frequency vibration possible. Mechanical rollers: Motor-driven; speed approximately 15 rpm (approximate value). Displays: 10.4" touchscreen console; selected heads with 2.4" mini displays. Service systems: Automatic cleaning/drainage in a vacuum system (V-Shape/V8 platform).
Accessories: - V8C2-HV11-02458 body roller head, - V8C2-HV12-02452 cavitation-RF head with three tips, - V8C2-HV15-01099 face/neck head with three tips, - V8C2-HV13-02480 medium extremity head, - VACUUM canister with tubing, - Footswitch, - Power cable, - Head cable stand, - Carrying case
Description of operation and purpose of the technical device The device is a platform for non-invasive cosmetic treatments combining several physical effects in a single base and four heads. It works by simultaneously applying vacuum, mechanical massage, radio waves (RF), infrared radiation (IR), and – in one of the heads – 60 kHz ultrasound (cavitation). Mechanisms of operation of individual modules: • Vacuum – creates a controlled skin-tissue fold, improves microcirculation and tissue movement; the suction channel ends with a separator/canister that protects the pump from liquids (collects fluids during operation and system flushing). • Mechanical rollers (in the large body head) – massage the tissues and facilitate even distribution of RF/IR energy. • RF (radio waves) – current with a frequency of ~0.5–1.0 MHz flows through tissues, causing resistive heating in a controlled volume (collagen modeling, firming). • IR (infrared approx. 850 nm) – superficial skin heating, preparing for RF/tissue mobilization. • 60 kHz cavitation (RF-integrated head) – intense ultrasonic stimulation of tissue fluids, used in cosmetology for body contouring treatments. • Control is via a touchscreen; parameters such as vacuum strength (continuous/pulse), time, RF/IR power, and roller mode are selected; activation usually occurs using a foot pedal. After the treatment, the vacuum path is rinsed with water/cleaning solution drawn through the head into the canister. Headset (typical): 1. Large head for the body – vacuum + rollers + RF + IR (specific body shaping treatments). 2. Medium head for the body/limbs – vacuum + RF + IR (medium areas). 3. Small head for the face/neck – vacuum + RF + IR (sensitive areas). 4. 60 kHz cavitation head + RF – body shaping treatments. The device is intended for performing aesthetic and cosmetic treatments in beauty/spa salons, in particular: • body contouring and reducing the appearance of cellulite (combined treatments: vacuum/rollers/RF/IR and cavitation+RF), • skin firming and tightening (RF/IR), • drainage and improvement of microcirculation, reducing local congestion (vacuum + mechanical massage), • facial, neck, and décolleté treatments (small vacuum head + RF + IR)
Technical Condition Description Nameplate: - Location – rear housing, - Tampering/irregularities – none. Identification Number Stamped: - Location – not located. Technical Documentation: - User Manual – none. - Parts Catalog – none. - Technical Specifications – none. - Device Technical Passport – none. CE/EC Certificate: - Marking – yes, - Declaration/Certificate of Conformity – not provided, Operation History: - Service Documentation – none, - Periodic Inspection Markings – none. Year of Manufacture: - 2020 – determined based on purchase documentation – information provided by the client. Technical Condition: - Visual – good, minor mechanical damage noted. - Operating wear – directly proportional to age, device not equipped with a treatment/operating time counter. - Operating system – device connected to a power source, starts up, navigation through the device's menu is flawless, the device reports no problems with the connected heads, treatments for individual heads are started, they start up, the pump is audible, the heads respond to control both from the control panel and the heads themselves. - Heads – with signs of use, dirty, surface scratches, the presence of liquid was detected after removing the head tips. - Control panel – monitor screen displays information correctly, minor scratches, touch response is correct. - External housing – front and rear housings have scratches. - Other – no information on operation or service history. |