Technical Device Data General Data: Brand, Model: BTL EXILIS ULTRA 360 Technical Device Type: Medical Device Serial Number: 71500B005068 Year of Manufacture: 2021 Mileage: 112 mth
Technical data of the item: Parameter Value / Notes Trade name Exilis Ultra 360 Manufacturer BTL Industries Ltd., Stevenage, UK Conformity marking CE 2460 Device weight 30 kg Date / production revision 2021-05-21 (v115 – unit; v102 applicator) SN (unit) 71500B005068 SN (applicator/cable) 215L0B006923 (with 0/O) LOT POP271185 REF A715.009 Power supply Power supply / 100–240 V AC, 50/60 Hz Fuse 2 × T4AL, 250 V Single-phase (from labels/markings) Single-phase (from labels/markings) Design / Interface Control Screen: Touchscreen, color Stationary aesthetic device RF+US (Exilis Ultra 360) Stationary aesthetic device RF+US (Exilis Ultra 360)
Equipment: - LARGE head, serial number 215L0B006923, production date: May 21, 2021, calibration date: May 19, 2021. - XP 2 head, serial number 215E0B002181, production date: June 1, 2021, calibration date: May 27, 2021.
Description of operation, intended use of the technical device EXILIS ULTRA 360 – a system for non-invasive body contouring and skin rejuvenation, combining RF and ultrasound; reduces localized fat tissue, visibly smoothes cellulite, improves firmness and elasticity, evens texture, and reduces wrinkles, providing a lifting and refreshing effect.
Technical documentation: - User's manual – none, - Parts catalog – none, - Technical specifications – none. CE/EC certificate: - Marking – yes, - Declaration/Certificate of Conformity – none. Operation history: - Service documentation – none. - Periodic inspection markings – yes – next 06.2026 Year of manufacture: - 2021 – determined based on the permanently affixed markings on the nameplate. Technical condition: - Visual appearance – good, the device requires thorough cleaning, minor scratches were found on the device's casing. - Wear – low, device mileage below the norm. - Operating system – the device is connected to a power source and starts up properly. Navigating the menu is smooth. The treatment has been initiated, the device reports no errors. The device has not been tested with the patient. - Transducers – with signs of use. The transducers have not been tested with the patient. The central unit did not display errors for the connected transducers when the treatment was running. - Control panel – the monitor screen is functional, with minor scratches. - Other – no information on the operation or service history is available. |